浪涌保護器與過電流保護器的配合使用

發表日(ri)期:05月09 2020 文章編輯:原創(chuang) 瀏(liu)覽次(ci)數:2455次(ci)

在綜合防雷工程中,往往會同時安裝(zhuang)浪涌(yong)(yong)保(bao)護器(qi)(qi)(qi)(SPD)和過(guo)電(dian)流保(bao)護器(qi)(qi)(qi),這兩(liang)者(zhe)要(yao)配(pei)合使用(yong)共同保(bao)護電(dian)氣線路(lu)的(de)安全。今天鈞和電(dian)子為您分享(xiang)浪涌(yong)(yong)保(bao)護器(qi)(qi)(qi)與過(guo)電(dian)流保(bao)護器(qi)(qi)(qi)的(de)配(pei)合使用(yong)。


鈞和電子分享浪涌保護器與過流保護器的配合使用


一、概述

按照相關(guan)規(gui)定(ding),為了確保(bao)低壓配電系(xi)統的正常運(yun)行,在浪涌(yong)保(bao)護器(qi)(qi)前(qian)端串聯(lian)匹配的低壓斷路(lu)器(qi)(qi)、熔斷器(qi)(qi)、空(kong)氣開關(guan)等過電流保(bao)護器(qi)(qi)。而在實(shi)際(ji)應用中,往往會出現(xian)浪涌(yong)保(bao)護器(qi)(qi)(SPD)與過電流保護器不匹配,過電流保護器提前動作,造成停電事故。這主要是因為當雷電(dian)過電(dian)壓首(shou)次侵(qin)入時,低壓斷路(lu)器(qi)(qi)就已(yi)經動作,盡(jin)管首(shou)次雷電(dian)過電(dian)壓已(yi)得到有效泄放,但是后(hou)續侵(qin)入時,設備就失去該級保(bao)護(hu)(hu)(hu)而損壞,該動作時不動作會使浪涌(yong)保(bao)護(hu)(hu)(hu)器(qi)(qi)的后(hou)續電(dian)流(liu)造成(cheng)主斷路(lu)器(qi)(qi)動作,影響了線路(lu)供(gong)電(dian)。特別是在浪涌(yong)保(bao)護(hu)(hu)(hu)器(qi)(qi)劣(lie)化程度比(bi)較高(gao)(gao),漏(lou)電(dian)流(liu)比(bi)較大的情況下,溫度驟然(ran)升(sheng)高(gao)(gao)會引發火災。由(you)此可見,浪涌(yong)保(bao)護(hu)(hu)(hu)器(qi)(qi)和過電(dian)流(liu)保(bao)護(hu)(hu)(hu)器(qi)(qi)的配合使用十(shi)分重要(yao)。

二、浪(lang)涌(yong)保護器和過電流保護器的工作原理

浪(lang)(lang)涌(yong)(yong)保(bao)護器(qi)(SPD)又被(bei)稱為(wei)電涌(yong)(yong)保(bao)護器(qi)、防雷器(qi)和避雷器(qi)等(deng),是低(di)壓配電系統中常(chang)(chang)用的防雷裝置,通常(chang)(chang)被(bei)并聯或串聯接入線路中,起到(dao)泄放浪(lang)(lang)涌(yong)(yong)、保(bao)護線路的作(zuo)用。根據其工作(zuo)原理的不同分為(wei)開關型(xing)浪(lang)(lang)涌(yong)(yong)保(bao)護器(qi)、限壓型(xing)浪(lang)(lang)涌(yong)(yong)保(bao)護器(qi)和組合型(xing)浪(lang)(lang)涌(yong)(yong)保(bao)護器(qi)。之前我們已經詳細介紹過它(ta)的工作(zuo)原理,若(ruo)有興趣可(ke)點擊“開關(guan)型和限壓(ya)型浪涌(yong)保護(hu)器的工作(zuo)原理(li)”查看。

過(guo)電(dian)流保護(hu)器(qi)常見的為空氣開關,它是一種只要有短(duan)路形成回(hui)路就(jiu)會跳閘的(de)(de)開關。熔(rong)斷器(qi)(qi)是一種結構(gou)簡單、使(shi)用(yong)方(fang)便、價格(ge)低廉的(de)(de)起保(bao)(bao)(bao)護(hu)作用(yong)的(de)(de)電(dian)(dian)(dian)器(qi)(qi),它串(chuan)聯(lian)在被保(bao)(bao)(bao)護(hu)電(dian)(dian)(dian)路中,當線路或(huo)電(dian)(dian)(dian)氣設備的(de)(de)電(dian)(dian)(dian)流(liu)(liu)超過規定值足夠(gou)長的(de)(de)時間后,其自身產生的(de)(de)熱(re)量能夠(gou)熔(rong)斷一個(ge)或(huo)幾個(ge)特殊設計的(de)(de)和(he)相(xiang)應(ying)的(de)(de)部(bu)件(jian),斷開其所(suo)接人的(de)(de)電(dian)(dian)(dian)路并分斷電(dian)(dian)(dian)源,從而起到保(bao)(bao)(bao)護(hu)作用(yong)。過流(liu)(liu)保(bao)(bao)(bao)護(hu)器(qi)(qi)廣泛(fan)應(ying)用(yong)于高低壓配電(dian)(dian)(dian)系統(tong)和(he)控(kong)制系統(tong)以及用(yong)電(dian)(dian)(dian)設備中,作為短(duan)路和(he)過電(dian)(dian)(dian)流(liu)(liu)的(de)(de)保(bao)(bao)(bao)護(hu)器(qi)(qi),是應(ying)用(yong)最普(pu)遍的(de)(de)保(bao)(bao)(bao)護(hu)器(qi)(qi)件(jian)之一。

三、浪涌保護器與過電(dian)流(liu)保護器應合理匹配

基于浪涌(yong)保(bao)護(hu)器和過(guo)電(dian)流保(bao)護(hu)器的(de)(de)工作(zuo)原理(li)(li),為了保(bao)證線路的(de)(de)用電(dian)安全,要(yao)合理(li)(li)選(xuan)用浪涌(yong)保(bao)護(hu)器和過(guo)電(dian)流保(bao)護(hu)器,在參數(shu)上要(yao)相互匹配,以(yi)保(bao)證在規定時間內可靠地有選(xuan)擇地切斷電(dian)路,即要(yao)求(qiu)最靠近故障點的(de)(de)保(bao)護(hu)電(dian)器動(dong)作(zuo),而其(qi)上級(ji)的(de)(de)保(bao)護(hu)電(dian)器不動(dong)作(zuo),使得被(bei)切斷電(dian)路的(de)(de)范圍最小,避免過(guo)電(dian)流保(bao)護(hu)器誤動(dong)作(zuo)造成供電(dian)中斷或設備損(sun)壞(huai)。

為了防(fang)止浪涌保(bao)(bao)護(hu)器(qi)的(de)(de)失效(xiao)故障,浪涌保(bao)(bao)護(hu)器(qi)前端安裝熱熔斷器(qi)過電流(liu)保(bao)(bao)護(hu)器(qi)。其前端過電流(liu)保(bao)(bao)護(hu)器(qi)的(de)(de)保(bao)(bao)險(xian)電流(liu)值與(yu)主電路上過電流(liu)保(bao)(bao)護(hu)器(qi)的(de)(de)保(bao)(bao)險(xian)電流(liu)值不宜小于1:1.6141。具體(ti)(ti)選型(xing)參數根據(ju)現場情(qing)況進行。

 

文章分享:
0

相關內容

logo